Volume 9 Preprint 1


Expert 3D software simulations compared with experimental data for the interference between a cathodically protected underground storage tank (UST) and a concrete foundation

B. Van den Bossche, M. Purcar, L. Bortels, A. Dorochenko and J. Deconinck

Keywords: cathodic protection simulations, advanced software package, multi-layer model

Abstract:

Because you are not logged-in to the journal, it is now our policy to display a 'text-only' version of the preprint. This version is obtained by extracting the text from the PDF or HTML file, and it is not guaranteed that the text will be a true image of the text of the paper. The text-only version is intended to act as a reference for search engines when they index the site, and it is not designed to be read by humans!

If you wish to view the human-readable version of the preprint, then please Register (if you have not already done so) and Login. Registration is completely free.

ISSN 1466-8858 Volume 9 Preprint 1 6 February 2006 Expert 3D software simulations compared with experimental data for the interference between a cathodically protected underground storage tank (UST) and a concrete foundation B. Van den Bossche+, M. Purcar+, L. Bortels +*, A. Dorochenko +, J. Deconinck++ + Elsyca N.V., Kranenberg 6, 1731 Zellik, Belgium ++ Vrije Universiteit Brussel, Department IR\ETEC, Pleinlaan 2, 1050 Brussels, Belgium leslie.bortels@elsyca.com ABSTRACT Elsyca CPMaster is a revolutionary 3D software tool for the design and optimisation of cathodic protection systems for burried and submerged structures. It provides the corrosion engineer an intelligent tool for managing operational costs, significantly reducing expensive commissioning surveys and costly repairs, adding major value to the cathodic protection business. Elsyca CPMaster is entirely integrated in SolidWorks® offering a user-friendly interface for the CP design, including file import from numerous other CAD packages. In this paper, Elsyca CPMaster simulations are compared to experimental data obtained by the Nederlandse Gasunie. The case that has been investigated is the interference between a cathodically protected underground storage tank (UST) and a concrete foundation. Experiments show that the protection level at the side of the UST near the concrete foundation is only –600 to –700 mV versus CSE, while the far field potential is about -1200 mV. The interference can be mitigated by putting a PVC screen between the UST and the concrete fundation. This increases the protection level on the tank with about -200 mV at the foundation side, while the potential at the other side of the tank is hardly affected. The agreement between the experimental data obtained on site and Elsyca CPMaster simulations, using a two-layer model that accounts for the ground water level, is very good. Keywords: cathodic protection simulations, advanced software package, multi-layer model 1 © University of Manchester and the authors 2005. This is a preprint of a paper that has been submitted for publication in the Journal of Corrosion Science and Engineering. It will be reviewed and, subject to the reviewers’ comments, be published online at http://www. corrosion.jcse in due course. Until such time as it has been fully published it should not normally be referenced in published work. ISSN 1466-8858 Volume 9 Preprint 1 6 February 2006 INTRODUCTION Cathodic Protection (CP) systems are widely applied to buried tank and pipeline structures, as they compensate (by electrochemical means) for the loss in physical protection due to the degradation of tank coatings over time. Most often, these CP systems contain a series of impressed current anode ground beds (though also sacrificial anodes can be used), placed at a remote distance from the pipes and tanks. The entire configuration of the CP system and the buried structures has some particular characteristics that necessitate and justify the use of numerical simulations. First, the hidden character and low accessibility of these structures make installation, maintenance and repair very expensive. Also, the geometry of most steel structures that are subject to cathodic protection is too complex to allow analytical or even empirical estimations for the determination of the local protection level. Numerical modeling provides significant relieve by pointing out insufficiently protected regions - possibly subject to corrosion, and overprotected regions - subject to hydrogen evolution and hence coating delamination or hydrogen embrittlement. As a consequence, numerical modeling allows simplification and optimization of installation, maintenance and repair. Moreover, models provide reference values for measurements on operational sites, enabling to trace and solve any possible anomaly. Most of the publications dealing with the computation of the CP of buried or submerged structures are based on the well known Boundary Element Method (BEM) [1]. Orazem et al. [2,3] use a 3D BEM approach to compute the protection level of large coating defects on pipelines. Results are presented for a pipe segment of limited length (10 feet), in presence of a parallel anode system. Riemer and Orazem [4] produced results for a larger pipeline (> 6 km) © University of Manchester and the authors 2005. This is a preprint of a paper that has been submitted for publication in the Journal of Corrosion Science and Engineering. It will be reviewed and, subject to the reviewers’ comments, be published online at http://www. corrosion.jcse in due course. Until such time as it has been fully published it should not normally be referenced in published work. ISSN 1466-8858 Volume 9 Preprint 1 6 February 2006 with coating defects of varying size, and investigated the ability of coupons in the vicinity of the defects to measure off-potentials. Adey [5] applied a full 3D approach to calculate the potential field in the neighbourhood of jacket joints under cathodic protection of sacrificial anodes. The present authors [6] used a 3D coupled multi-domain BEM approach to simulate the protection level of a buried pipe segment surrounded by a U-shaped concrete vault. The simulations presented in this paper are obtained using the Elsyca CPMaster software package [7] with fundamentals as decribed in the next section. MATHEMATICAL MODEL Elsyca CPMaster is entirely integrated in SolidWorks® offering a user-friendly interface for the CP design, including file import from numerous other CAD packages. The mathematical model is based on the so-called Potential Model with key features are listed below: • Parameterisation of all geometrical dimensions • Simulation of 3D CP-configurations with arbitrary complexity (including position and shape of ground beds, casings, ....) • Interference from 3rd party CP-systems • Ohmic drop effects in the soil or water • Anodic and cathodic reaction polarization behavior • Impressed current and sacrificial ground beds / anodes • Floating (not contacted) electrodes (for example casings) • Multi-layered soils with varying resistivity • Local metal dissolution calculation based on Faraday’s law. © University of Manchester and the authors 2005. This is a preprint of a paper that has been submitted for publication in the Journal of Corrosion Science and Engineering. It will be reviewed and, subject to the reviewers’ comments, be published online at http://www. corrosion.jcse in due course. Until such time as it has been fully published it should not normally be referenced in published work. ISSN 1466-8858 Volume 9 Preprint 1 6 February 2006 The resulting non-linear system equations are solved using a Newton-Raphson iterative method [8], combined with an advanced linear solver to solve the linear system of equations that appears during each iteration in the Newton-Raphson procedure. An automated hybrid grid generator is used to produce the high quality meshes that are required for the computations [9]. Full details can be found in reference [6]. DESCRIPTION OF THE PROBLEM The configuration of interest consists of a buried tank with concrete foundation (the latter assumed to be non-conducting) and part of steel reinforced concrete foundation of a neighbouring building (figure 1). The foundation is electrically connected to the CP system, hence exhibits a negative impact on the protection level of the tank surface. An insulating screen is installed between the tank and the foundation in order to limit the impact of the concrete foundation. Figure 1: configuration of tank, foundation, screen and surrounding computational domain (front and back side not shown - dimensions in mm). © University of Manchester and the authors 2005. This is a preprint of a paper that has been submitted for publication in the Journal of Corrosion Science and Engineering. It will be reviewed and, subject to the reviewers’ comments, be published online at http://www. corrosion.jcse in due course. Until such time as it has been fully published it should not normally be referenced in published work. ISSN 1466-8858 Volume 9 Preprint 1 6 February 2006 The tank has a diameter of 1.3 m, 4 m length and is positioned about 0.9 m below the earth surface (figure 2). For computational purposes, a sufficiently large box has been defined that surrounds the configuration of interest, the top plane coinciding with the earth surface and the side wall opposite to the tank being identified with the far field. Also a series of small cubes has been defined, representing possible positions of the reference electrode in perforated probe tubes. These small cubes are considered insulating, hence do not affect the current density distribution in the soil, they simply take the potential of the surrounding soil. Figure 2: Detail of tank, foundation and screen. DETERMINATION OF THE POLARIZATION DATA The corrosion potential (Ecorr1 = -476 mV vs CSE) and the polarization behaviour of bare steel in contact with sand are taken from measurements presented before [6 – type B soil]: j f ( V U ) . (1) For the concrete foundation, the concrete acts as an additional resistive layer between the steel skeleton and the soil. The corrosion potential steel / concrete takes an entirely different value © University of Manchester and the authors 2005. This is a preprint of a paper that has been submitted for publication in the Journal of Corrosion Science and Engineering. It will be reviewed and, subject to the reviewers’ comments, be published online at http://www. corrosion.jcse in due course. Until such time as it has been fully published it should not normally be referenced in published work. ISSN 1466-8858 Volume 9 Preprint 1 6 February 2006 Ecorr2 = – 200 mV vs Cu/Cu-sulphate (compared to Ecorr1 ). Neglecting the steel / concrete polarisation, and assuming a linear behaviour for the concrete resistance allows to describe the steel / concrete / soil interface by: V U E corr 2 con * L * j . with: j cathodic current density (A/m2).;  V metal potential (V); U grond potential (V); L average concrete thickness between steel and grond;  (2) con resistivity of concrete (.m). Currrent values for con range between 1.000 and 10.000 .m [10]. For the simulations performed in this paper the value is 10.000 .m as will be explained in more detail below. For the coated tank, it is assumed that the resistance of the coating is in series with the polarization resistance of the system steel/sand: j f (V U Lcoat * j) . (3) The value of L coat is not known a priori. It can be calculated from the fact that a current density j of -5.0E-6 A/m2 is needed [10] to obtain a minimum protection level V-U of –850 mV vs CSE. As a result a value of L coat = 80.000 . m2 is obtained. The curve presented by equation (3) exhibits a linear behaviour due to the high value for the coating resistance. © University of Manchester and the authors 2005. This is a preprint of a paper that has been submitted for publication in the Journal of Corrosion Science and Engineering. It will be reviewed and, subject to the reviewers’ comments, be published online at http://www. corrosion.jcse in due course. Until such time as it has been fully published it should not normally be referenced in published work. ISSN 1466-8858 Volume 9 Preprint 1 6 February 2006 RESULTS Model with uniform resistivity The computational domain surrounding the tank and foundation is taken big enough in order to ensure that the side walls and bottom can be considered as ”far field”. The far field potential has been taken from measurements [11] and yields 1984 mV (average of two measurements (2011 and 1958 mV). The measured soil resistivity [11] is 780 .m (average value at different depths). The values for the resisitivity and characteristic thickness of the concrete around the rebar are tuned based on comparison between measured and simulated tank-to-soil potentials at the earth surface (situation with screen). Measured values for the tank-to-soil potentials [11] are about -700 mV (vs CSE) for the foundation side of the tank and about -1200 mV (vs CSE) for the far field side, as measured with respect to the perforated measurement tubes. This results in the following values: con = 10.000 .m and L = 10 cm. Results are presented in Figure 3 for one of the trajectories for which data have been measured. The distance between the concrete foundation (left) and the far field (right) is 30 m. Figure 3: Earth potential (in V). Comparison between simulations (top) and measurements (below). © University of Manchester and the authors 2005. This is a preprint of a paper that has been submitted for publication in the Journal of Corrosion Science and Engineering. It will be reviewed and, subject to the reviewers’ comments, be published online at http://www. corrosion.jcse in due course. Until such time as it has been fully published it should not normally be referenced in published work. ISSN 1466-8858 Volume 9 Preprint 1 6 February 2006 The comparison between the simulated and measured potentials in the first meters around the foundation is very good. Away from the foundation however, discrepancies up to about 200 mV can be observed. It has to be said here that the current model assumes a uniform soil resistivity while in practise there is a second, less resistive, layer which will be accounted for later in this work. The actual protection level at the tank surface can easily be calculated as V – U. Since the metal potential V at the tank is 0 V, the protection level obtained is simply –U. The simulated soil potential around the tank and at the reference points is presented in Figures 4 and 5. The average protection level at the foundation side of the tank increases with about 200 mV after introduction of the PVC screen, while at the other side the changes are much less pronounced. One can easily observe that the highest protection level at the far field side of the tank (not including tank foundation!) indeed is –1200 mV (vs CSE), while at the foundation side of the tank, the protection level drops to about –800 mV (vs CSE). A detailed comparison between the simulated and measured tank-to-soil potentials is presented in tabels 1 (far field side) and 2 (foundation side) for the situation with screen. Important remark: From tables 1 and 2, it can be seen that the simulated tank-to-soil potential differ from the experimental values obtained in the reference points (‘cubes”). This is partly due to the fact that the measuring tubes are located at some distance from the tank. From the simulations it can be observed that the potential of the reference points differs about 100 mV from the actual soil potential near the tank. This means that the measured value at the far field of the tank are too optimistic while at the other side of the tank, the values are too low . © University of Manchester and the authors 2005. This is a preprint of a paper that has been submitted for publication in the Journal of Corrosion Science and Engineering. It will be reviewed and, subject to the reviewers’ comments, be published online at http://www. corrosion.jcse in due course. Until such time as it has been fully published it should not normally be referenced in published work. ISSN 1466-8858 Volume 9 Preprint 1 6 February 2006 Figure 4: Soil potential (V) around tank (situation without screen). Figure 5: Soil potential (V) around tank (situation with screen). © University of Manchester and the authors 2005. This is a preprint of a paper that has been submitted for publication in the Journal of Corrosion Science and Engineering. It will be reviewed and, subject to the reviewers’ comments, be published online at http://www. corrosion.jcse in due course. Until such time as it has been fully published it should not normally be referenced in published work. ISSN 1466-8858 Volume 9 Preprint 1 Depth [mm] -500 Left -1289 Middle -1285 6 February 2006 Right -1277 -1000 -1474 -1295 -1489 -1291 -1500 -1288 -1500 -1484 -1303 -1493 -1300 -1505 -1297 -2000 -1492 -1309 -1500 -1309 -1515 -1307 -2500 -1510 -1318 -1519 -1315 -1535 -1312 -3000 -1515 -1328 -1529 -1322 -1540 -1319 Table 1: Tank-to-soil potential (mV vs CSE) at the far field side (single layer model) for all reference locations. Measured values in black (left) – simulated values in red (right). Depth [mm] -500 Left -1059 Middle -1059 Right -1056 -1000 -1228 -1083 -1202 -1084 -1177 -1079 -1500 -1255 -1101 -1228 -1103 -1208 -1100 -2000 -1276 -1125 -1253 -1126 -1244 -1124 -2500 -1310 -1146 -1298 -1156 -1280 -1152 -3000 -1324 -1163 -1305 -1165 -1290 -1161 Table 2: Tank-to-soil potential (mV vs CSE) at the foundation side (single layer model) for all reference locations. Measured values in black (left) – simulated values in red (right). Two-layer model In the previous section it has been observed that the simulated potential at the earth surface at larger distances from the foundation differed +/- 200 mV from the measured data (see Figure 3). This discrepancy in results is due to the fact that the soil resistivity has been assumed to be uniform. In this section, a two-layer model will be introduced. The top layer has a uniform soil resistivity with the same value as before (i.e. 780 m). The thickness and resistivity of the © University of Manchester and the authors 2005. This is a preprint of a paper that has been submitted for publication in the Journal of Corrosion Science and Engineering. It will be reviewed and, subject to the reviewers’ comments, be published online at http://www. corrosion.jcse in due course. Until such time as it has been fully published it should not normally be referenced in published work. ISSN 1466-8858 Volume 9 Preprint 1 6 February 2006 second, less resistive layer (accounting for the grond water), will be tuned in order to match the measured potential vales at the earth surface with the simulations. The resistivity of the second layer allows to fit the potential near the concrete foundation while the starting depth of the grond water level allows to fit the potentials at larger distances. From this it turns out that a resistivity value for the second layer of about 150 m, starting from a depth of about 5 m, yields a very good agreement between the measured and simulated earth potentials over the complete trajectory (30 m in length). 2.5 Earth potential [V] 2 1.5 1 0.5 0 0 5 10 15 20 25 30 35 Distance to foundation [m] Figure 5: Earth potential (in V) as a function of distance (in m) to foundation. Measured values (), single layer model simulations with = 780 m (---) double layer model simulations with = 780 m/150 m (---). A detailed comparison between the simulated and measured tank-to-soil potentials for the two layer model is presented in tabel 3 (far field side) and 4 (foundation side) for the situation with screen. It can be seen that the agreement between both values is very good for the first 1.5 m while for the reference points at deeper locations the discrepancy is a little higher. This © University of Manchester and the authors 2005. This is a preprint of a paper that has been submitted for publication in the Journal of Corrosion Science and Engineering. It will be reviewed and, subject to the reviewers’ comments, be published online at http://www. corrosion.jcse in due course. Until such time as it has been fully published it should not normally be referenced in published work. ISSN 1466-8858 Volume 9 Preprint 1 6 February 2006 suggests that we are indeed close to the optimal combination for the start point and resistivity of the second layer. Depth [mm] -500 Left -1509 Middle -1506 Right -1506 -1000 -1474 -1523 -1489 -1522 -1500 -1520 -1500 -1484 -1539 -1493 -1540 -1505 -1539 -2000 -1492 -1561 -1500 -1563 -1515 -1560 -2500 -1510 -1582 -1519 -1584 -1535 -1584 -3000 -1515 -1600 -1529 -1606 -1540 -1606 Table 3: Tank-to-soil potential (mV vs CSE) at the far field side (two layer model) for all reference locations. Measured values in black (left) – simulated values in red (right). Depth [mm] -500 Left -1193 Middle -1203 Right -1197 -1000 -1228 -1239 -1202 -1254 -1177 -1251 -1500 -1255 -1285 -1228 -1302 -1208 -1299 -2000 -1276 -1333 -1253 -1352 -1244 -1352 -2500 -1310 -1392 -1298 -1422 -1280 -1422 -3000 -1324 -1438 -1305 -1455 -1290 -1456 Table 4: Tank-to-soil potential (mV vs CSE) at the foundation side (two layer model) for all reference locations. Measured values in black (left) – simulated values in red (right). CONCLUSIONS In this paper a revolutionary 3D software tool for the design and optimisation of cathodic protection systems for burried and submerged structures has been presented. The integration of the package in a professional CAD environment (SolidWorks®), allows to optimize the © University of Manchester and the authors 2005. This is a preprint of a paper that has been submitted for publication in the Journal of Corrosion Science and Engineering. It will be reviewed and, subject to the reviewers’ comments, be published online at http://www. corrosion.jcse in due course. Until such time as it has been fully published it should not normally be referenced in published work. ISSN 1466-8858 Volume 9 Preprint 1 6 February 2006 cathodic protection configuration (e.g. size and location of PVC screen, anode location, …) in a fast and flexible manner. Using the software package, the interference between a cathodically protected underground storage tank (UST) and a concrete foundation has been investigated. The resistivity of the concrete has been tuned such that the measured and simulated ground level potentials match. A first set of simulations, based on a uniform soil resistivity, predicts that the presence of a PVC screen between tank and foundation increases the protection level of the tank at the foundation side with about 150 to 200 mV. The measured and simulated values show a discrepancy of about 150 mV which already manifests itself in the far field region. This suggests the presence of a multi-layer soil with varying resistivity, coupled with the grond water level. A second set of simulations based on a two layer model, with the second layer being much less resistive, shows very good agreement between the measured and simulated earth level potentials. Comparison between measured and simulated tank potentials suggests that the choosen values are close to the optimal combination for the start point and resistivity of the second layer. ACKNOWLEDGEMENTS The authors wish to thank Ir. Pieter Stehouwer, Ir. Ing. Arie Dam and Ir. Kees Dijkstra, Nederlandse Gasunie, Groningen, Nederland for their excellent help in providing and discussing the experimental data. REFERENCES © University of Manchester and the authors 2005. This is a preprint of a paper that has been submitted for publication in the Journal of Corrosion Science and Engineering. It will be reviewed and, subject to the reviewers’ comments, be published online at http://www. corrosion.jcse in due course. Until such time as it has been fully published it should not normally be referenced in published work. ISSN 1466-8858 Volume 9 Preprint 1 6 February 2006 [1] C.A. Brebbia, Boundary Element Techniques – Theory and Applications in Engineering, Springer-Verlag Berlin, Heidelberg, 1983. [2] M.E. Orazem, J.M. Esteban, K.J. Kennelley, R.M. Degerstedt, Corrosion 53(1997)427. [3] M.E. Orazem, J.M. Esteban, K.J. Kennelley, R.M. Degerstedt, Corrosion 53(1997)264. [4] D.P. Riemer, and M.E. Orazem, Corrosion 56(2000)794. [5] R.A. Adey, Topics in Boundary Element Research, vol. 7, Electrical Engineering Applications, chapter 3, Springer-Verlag Berlin, Heidelberg 1990. [6] M. Purcar, B. Van den Bossche, L. Bortels, J. Deconinck, P.Wesselius, Corrosion 59 (2003) 1019. [7] CPMasterV1.0, User Manual, www.elsyca.com. [8] J. Deconinck, Current distributions and Electrode Shape Changes in Electrochemical Systems, Lecture Notes in Engineering 75, Springer Verlag Berlin, ISBN 3-540-551042, 1992. [9] Athanasiadis A.N., Deconinck H., Int. J. Numer. Meth. Eng. 58 (2003) 301 [10] Gasunie, OSB Voortgangsrapportage-001 (Internal Report), 30 January 2004. [11] Hommema, (Internal Report), 27 May 2005. © University of Manchester and the authors 2005. This is a preprint of a paper that has been submitted for publication in the Journal of Corrosion Science and Engineering. It will be reviewed and, subject to the reviewers’ comments, be published online at http://www. corrosion.jcse in due course. Until such time as it has been fully published it should not normally be referenced in published work.